The roof gets the attention, but the electrical panel decides how a solar system connects — and sometimes whether a panel upgrade is part of the project.

Updated 2026-10-15

The 120% rule

For load-side connections, NEC 705.12 limits the sum of 125% of the inverter output current plus the main breaker rating to 120% of the busbar rating. On a 200A bus with a 200A main, that allows about 40A of breaker, or roughly a 32A inverter output. Larger systems need another approach.

Ways around a small busbar

Electricians commonly use:

  • Main-breaker derate (e.g., 200A main to 175A) if the load calculation allows
  • Supply-side (line-side) tap ahead of the main breaker
  • Panel replacement with a higher-rated busbar
  • Center-fed panels or solar-ready panels with dedicated provisions

Rapid shutdown, disconnects, and labeling

NEC 690.12 requires rapid shutdown for rooftop arrays so firefighters can de-energize conductors on the roof. Utilities often require a visible, lockable AC disconnect near the meter, and the code requires specific warning labels at the panel and service. These are inspection items, so ask your installer how they'll be handled.

Find a pro

Compare solar & backup power specialists

Frequently asked questions

Do I need a licensed electrician for solar?

The electrical portion of a solar install must be done under a license that covers it — an electrical contractor or a solar specialty license, depending on your state.

Will solar keep my power on during an outage?

Grid-tied solar without a battery shuts off during outages for line-worker safety. You need a battery or a specific backup-capable inverter for outage power.

Can I add more panels later?

Often, but busbar limits and inverter capacity may require electrical changes. Mention expansion plans at design time.

Back to the solar & backup power guide

More in Solar & Backup Power

This guide is general information, not engineering or legal advice. Electrical codes are adopted and amended locally — consult a licensed electrician and your local building department for your project.